Critical Environment Technologies
Product List
-
Applications
Critical Environment is the leader in gas detection .It can be used in the following applications.
- Boiler Room: Continuous monitoring of natural gas and carbon monoxide in forced air central heating systems.
- Commercial Kitchen: Continuous monitoring of natural gas (or propane) and carbon monoxide in a commercial kitchen.
- Refrigeration Applications: Continuous monitoring of refrigerants in mechanical rooms . Early detection of refrigerant leaks .
- Indoor Pool Applications: Continuous monitoring of Chlorine and Ozone for indoor swimming pools in recreational facilities or hotels.
- Enclosed Parking Applications: Continuous monitoring of carbon monoxide and nitrogen dioxide in large parking garages.
- Greenhouse Applications:Continuous monitoring of ethylene and carbon monoxide in production greenhouses.
- MRI Room Applications: Continuous monitoring of oxygen in MRI rooms for hospitals & clinics.
- Hotel Applications: Continuous monitoring of refrigerant gas leaks from air conditioning units in hotel rooms.
- Waste Water Treatment Plant Applications: Continuous monitoring of common hazardous gases found in waste water treatment plants.
- Welding Shop Applications: Continuous monitoring of carbon monoxide and nitrogen dioxide in a welding shop.
- Ice Arena Applications: Continuous monitoring of ammonia, carbon monoxide, nitrogen dioxide and propane (or methane) in ice rinks.
- Battery Charging Applications: Continuous monitoring of hydrogen gas at lead acid battery charging stations.
- Distribution Warehouse Applications: Continuous monitoring of Carbon monoxide and Nitrogen dioxide in distribution warehouses.
-
YESAIR 8-Channel IAQ Monitor
Download CatalogThe YESAIR is a battery powered, portable air quality detection and data logging instrument designed for intermittent or continuous indoor air quality monitoring.
It is available in two models (Pump or Diffusion). Each can be configured as a multi-channel operation, with a selection of more than 30 different plug and play gas sensors, including a particulate sensor and an optional huge capacity data logging SD memory card. Both models come with one temperature sensor, one relative humidity (RH) sensor, the capacity for 5 internal gas sensors consisting of a maximum of three electrochemical toxic gas or oxygen sensors plus two high current draw sensors such as an infrared, PID, catalytic or particulate sensor. -
YES Plus LGA 15-Channel IAQ Monitor
Download CatalogYES Plus LGA is a multi-gas air quality monitoring and information recording instrument that simultaneously measures and records up to fifteen sensors. With more than 30 different plug and play sensors to select from, users can accurately monitor more within a single, easy to carry instrument.
Featuring a 15 channel sensor capacity including RH and temperature, YES Plus LGA can handle up to 12 additional plug & play sensors consisting of a maximum of 8 electrochemical toxic gas or oxygen sensors, 4 high current draw sensors such as an infrared, PID or catalytic, plus a remote YESDUST particulate sensor. -
Particulate Sensor
Download CatalogNew particulate sensor options for the YESAIR. Replacing the YESDUST, the PM2.5 or PM10 Particulate Sensor is externally mounted on the YESAIR allowing for easy holding and mobility. The particulate sensor detects smoke, dust, pollen, spores, etc. particle concentrations in air by using an optical sensing method.
Ideal for indoor air quality monitoring, and applications associated with air cleaners and purifiers, air conditioners, HVAC and outdoor dust monitoring.
-
Smart Gas Sensors
Download CatalogSensors Technology:
- Electrochemical: Toxic gas sensors & oxygen sensors. Lifespan is 2 - 5 years (sensor type & manufacturer dependent). Oxygen typically 3 years.
- Catalytic: Combustible gas sensors, toxic gas sensors at very high concentrations (% volume). Lidespan is 3 - 8 years (typically if not poisoned).
- Infrared: Toxic, combustible & refrigerant gas sensors.Lifespan is 10 years +.
- PID / TVOC: Toxic gas sensors, organic compounds & chemical. Lifespan is 3 - 8 years (typically if not contaminated and with regular maintenance).
Gas Sensors: Ammonia (NH3), Arsine (AsH3), Carbon dioxide (CO2), Carbon monoxide (CO), Chlorine (Cl2), Chlorine dioxide (ClO2), Ethylene (C2H4), Ethylene oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen chloride (HCl), Hydrogen cyanide (HCN), Hydrogen fluoride (HF), Hydrogen sulphide (H2S), Methane (CH4), Nitric oxide (NO), Nitrogen dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur dioxide (SO2), TVOCs.
-
Sampling Probes
YESAIR Sampling Probe
Handheld sampling probe to attach to the YESAIR for sampling areas that are difficult to reach.
YES Plus LGA Sampling Probe
Handheld sampling probe to attach to the YES Plus LGA for sampling areas that are difficult to reach.
-
YES Logger Package
A package of items required to save, retrieve and review data logged by the YESAIR or Yes Plus LGA IAQ monitors
Includes a 2GB SD flash card, 6 ft USB cable, USB multi card reader, 512 MB USB thumb drive with the YESViewer Software and the YESViewer Software Manual.
-
cGas Detector for Indoor Public Spaces
Download CatalogFor monitoring: Carbon dioxide, Carbon monoxide, Formaldehyde, TVOCs, Particulates, RH & Temperature, Refrigerants
One or two channel gas detector with an aesthetically pleasing design to reduce noticeability when used in publicly occupied spaces such as hotels and schools ,Office Buildings,Hospitals, Apartment Buildings, Retirement Homes,Theatres/Auditoriums, Schools/Universities/Dormitories and many more...
-
cGas Detector Carbon Dioxide (CO2) Transmitter
Download CatalogFor monitoring: Carbon dioxide
Low maintenance Carbon dioxide (CO2) gas detector available in ppm or %vol with Plug & Play Smart Sensor Technology
It can be used in Greenhouses,Wineries,Breweries, Marine Vessels,Fruit Ripening Rooms, CO2 Fire Suppression,CO2 Storage Rooms,CO2 Refrigeration Systems ,Beverage Bottling Facilities
-
cGas Detector Digital Transmitter
Download CatalogFor monitoring: Ammonia, Carbon monoxide, Carbon dioxide, Chlorine, Ethylene, Ethylene oxide, Fluorine, Formaldehyde, Hydrogen, Hydrogen sulphide, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulfur dioxide, Methane, Propane, Hydrogen, TVOCs, Refrigerants
One or two channel Modbus® or BACnet® gas detector with flexible customization options and Plug & Play Smart Sensor Technology.
Main applications are in Parking Facilities,Vehicle Repair Shops, Ice Arenas, Swimming Pools, Refrigeration Rooms,Chiller Rooms,Battery Charging Rooms ,Manufacturing Plants ,Maintenance Facilities and many more
-
ESH-A Remote Sensor
Download CatalogFor monitoring: Methane, Propane, Hydrogen, TVOCs
Single analog remote sensor for flexible location monitoring.
The main aplications are in parking facilities,Parking Facilities ,Vehicle Repair Shops ,Equipment / Machinery Rooms ,Manufacturing Plants ,Food Processing Plants ,Battery Charging Rooms and many more...
-
LPT Low Power Transmitter
Download CatalogFor monitoring: Ammonia, Carbon monoxide, Nitrogen dioxide, Chlorine, Ozone or Oxygen
Single channel, analog gas detector for enclosed parking facilities, recreational facilities, oxygen depletion applications
It can used at Parking Facilities ,Vehicle Repair Shops ,Manufacturing Plants ,Maintenance Facilities ,Ice Rinks ,Aquatic Facilities ,Chiller Rooms ,Chemical Storage Rooms , Oxygen Depletion and many more...
-
LPT-A Analog Transmitter
Download CatalogFor monitoring: Ammonia, Carbon monoxide, Chlorine dioxide, Chlorine, Ethylene, Ethylene oxide, Fluorine, Formaldehyde, Hydrogen, Hydrogen sulphide, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulfur dioxide, Methane, Propane, Hydrogen, TVOCs, Refrigerants
Single channel, analog gas detector with many gas sensor choices
It can be used in Parking Facilities,Vehicle Repair Shops, Arenas and Pools, Refrigeration Rooms, Chiller Rooms, Battery Charging Rooms, Hotels, Airports and many more...
-
LPT-P Digital Car Park Transmitter
Download CatalogFor monitoring: Carbon monoxide, Nitrogen dioxide, Methane, Propane, Hydrogen
3 channel, digital (Modbus®) gas detector for enclosed parking facilities
Main applications are in Parking Facilities ,Vehicle Repair Shops ,Electric Car Charging Stations ,Battery Charging Rooms and many more...
-
LPT-M Modbus® Transmitter
Download CatalogFor monitoring: Ammonia, Carbon monoxide, Chlorine dioxide, Chlorine, Ethylene, Ethylene oxide, Fluorine, Formaldehyde, Hydrogen, Hydrogen sulphide, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulfur dioxide, Methane, Propane, Hydrogen, TVOCs
A full featured, 3 channel, digital (Modbus®) gas detector with many gas sensor choices
Main applications are in parking facilities, Arenas and Pools ,Chiller Rooms ,Manufacturing Plants ,Maintenance Facilities ,Food Processing Plants and many more...
-
LPT-B BACnet® Transmitter
Download CatalogFor monitoring: Ammonia, Carbon monoxide, Chlorine dioxide, Chlorine, Ethylene, Ethylene oxide, Fluorine, Formaldehyde, Hydrogen, Hydrogen sulphide, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulfur dioxide, Methane, Propane, Hydrogen, TVOCs
A full featured, 3 channel, digital (BACnet®) gas detector with many gas sensor choices, intended to be used alone or integrated into an existing BACnet® network
It can be used in Parking Facilities ,Arenas and Pools, Chiller Rooms, Manufacturing Plants, Maintenance Facilities, Food Processing Plants, Ice Cleaning Machine Rooms and many more...
-
CXT Explosion Proof Transmitter
Download CatalogFor monitoring: Ammonia, Carbon monoxide, Nitrogen dioxide, Oxygen, Hydrogen sulphide, Sulfur dioxide, Methane, Propane, Hydrogen, Acetylene, Butane, Ethanol, Heptane, Hexane, Isopropyl alcohol, Toluene, Pentane, Ethylene, Diesel fuel vapour
Reliable, accurate monitoring of toxic or combustible gases in potentially explosive and harsh environments, including hazardous-rated areas.
The main applications are in Industrial / Commercial Buildings,Onshore Oil & Gas Terminals Utilities, Power Plants, Refineries, Chemical Plants. Deep Freezer Rooms, Chiller Rooms and many more...
-
ART Infrared Refrigerant Transmitter
Download CatalogFor monitoring: refrigerants R22, R32, R123, R134A, R404A, R407A, R407C, R407F, R410A, R422A, R422D, R427A, R448A, R449A, R452A, R507, R513A, R514A, HFO1234YF, HFO1234ZE, HFO1233ZD
Single channel, infrared refrigerant gas detector with accurate, low level leak detection, available with analog or Modbus® output
It can be used in Supermarkets/Convenience Stores, Refrigerated Mechanical Rooms, Commercial Chiller Equipment Food Storage/Freezer Rooms, Food Processing Plants and many more...
-
AST-ICD & AST-IHC Industrial Infrared Transmitters
Download CatalogFor monitoring: Carbon dioxide, Hydrocarbons, Methane and jet fuel vapours
Industrial, high quality analog gas detectors with dual beam, miniature infrared gas sensors
It can be used in Commercial Buildings, Institutional Buildings, Waste Water Treatment Plants, Oil & Gas Plants, Manufacturing Plants, and many more...
-
AST-IS1 Standard CO2 Transmitter
Download CatalogA simple, economical infrared Carbon dioxide analog gas detector with a 0 - 2,000 ppm measurement range.
Comes in a simple, general purpose wall mount enclosure for installation in the climate zone.
The main applications are in Residential Buildings ,Commercial Buildings ,Schools / Educational Institutions ,Offices and many more...
-
AST-IS3 Industrial CO2 Transmitter
Download CatalogInfrared Carbon dioxide analog gas detector with a 0 - 2,000 ppm measurement range for mounting in ventilation ducts.
Comes in a in a water tight, duct style enclosure without a display.
The main applications are in commercial Buildings,Schools / Educational Institutions,Office Buildings and many more...
-
AST-IS12 Industrial CO2 Transmitter
Infrared Carbon dioxide Modbus® gas detector with a 0 - 2,000 ppm measurement range housed in a water tight, duct style enclosure for mounting in ventilation ducts
Comes with Modbus® output, a display and relay
The main applications are in Commercial Buildings, Schools / Educational Institutions ,Office Buildings and many more...
-
FCS-8 Flexible Control System (up to 8 Channels)
Download Catalog8 channel high performance Controller with logic control and priority settings for smaller gas detection applications.
Available with Modbus® or BACnet® communication with BAS, supports 4-20 mA and Modbus® driven VFDs.
The main applications are in smaller Parking Facilities ,Recreation Facilities ,Food Processing Plants ,Cold Storage / Freezer Rooms ,Chemical Storage Rooms and many more...
-
FCS Flexible Control System (up to 128 Channels)
Download Catalog128 channel high performance Controller with logic control and priority settings for mid to large gas detection applications
Available with Modbus® or BACnet® communication with BAS, supports 4-20 mA and Modbus® driven VFDs
The Main applications are in Large Parking Facilities ,Recreation Facilities ,Food Processing Plants , Cold Storage / Freezer Rooms ,Chemical Storage Rooms and many more...
-
QCC Quad Channel Controller
Download Catalog4 Channel Controller with logic control for small to medium gas detection applications
Available with Modbus® or BACnet® output for communicating with a BAS, DDC or other control panel
It can be used in Large Parking Facilities ,Recreation Facilities ,Food Processing Plants ,Cold Storage / Freezer Rooms, Chemical Storage Rooms and many more...
-
SCC Self Contained Controller
Download Catalog2 channel dependable self-contained Controller with flexible internal and/or remote sensor configurations
Features LED indicators and one configurable 4-20 mA input; for monitoring: Carbon monoxide, Nitrogen dioxide, Hydrogen, Methane, Propane
The main Applications are in Parking Facilities ,Vehicle Repair Shops ,Battery Charging Rooms ,Buildings on Landfill Sites and many more...
-
DCC Dual Channel Controller
Download Catalog2 channel versatile self-contained Controller with VFD capabilities and flexible internal and/or remote sensor configurations
Features two 4-20 mA outputs and one configurable 4-20 mA input; for monitoring: Carbon monoxide, Nitrogen dioxide, Nitric oxide, Oxygen, Hydrogen sulphide, Ethylene, Sulphur dioxide, Hydrogen, Methane, Propane, TVOCs

